ARTSTONE
Home / Foundation Series

Foundation Series

Two Ready-to-Fix walls.
Two distinct products.

Choose a fully integrated customized wall made around your project, or an architecturally finished interlocking wall block. Each has a distinct product form and scope.

Illustrative ARTSTONE architectural or product concept
Architectural / product concept

The Ready-to-Fix wall offering

Choose the product that fits your scope.

ProductDefining formScope of integration
Fully Integrated Customized WallWall produced to the approved project layout and dimensions.Selected finishes, openings, fitted components and agreed building-service provisions.
Architecturally Finished Interlocking Wall BlockInterlocking block with an architectural face and matching rear geometry.Male / female engagement and horizontal / vertical conduit channels as identified in the datasheet.

Type 01

Fully Integrated
Customized Wall.

The customized wall is developed around the project’s layout, dimensions and architectural selections. Doors, windows, frames, fittings and specified electrical or plumbing provisions are coordinated before manufacture.

Its scope is defined as a wall package for the approved building, with the structural role, reinforcement, connections and site-completion interfaces established in the project design.

Customized-wall applications

Exterior character. Interior continuity.

  • Exterior walls and façadesSelect finishes that establish the architectural appearance, with weather exposure and perimeter details addressed by the specification.
  • Interior walls and partitionsCoordinate room layouts, openings and functions, distinguishing partitions from load-bearing walls.
  • Wet areas and reception spacesChoose finishes for the location, including cleaning, moisture exposure, joints and maintenance requirements.

Two structural classifications

Structure wall. Partition wall.

Alongside the two product formats, Ready-to-Fix walls are classified by their role in the building. Both have a 4 cm concrete surface on each side. Their total thickness and central connections distinguish the structural and partition configurations.

ClassificationTotal thicknessTwo facesCentral arrangementBuilding role
Structure wall25 cm4 cm on each sideConcrete braces within the central zoneLoad-bearing, with braces and connections designed for the building loads.
Partition wall15 cm4 cm on each sideJoiners within the central zoneNon-load-bearing division of spaces within the structural system.

Inside the wall

Two finished faces. A purpose-built centre.

Structure wall · 25 cm

4 cm
Face
17 cm central zone
Load-bearing concrete braces
4 cm
Face

The concrete braces provide the central load-bearing arrangement. Brace geometry, reinforcement, foundations and connections follow the approved structural design.

Partition wall · 15 cm

4 cm
Face
7 cm central zone
Joiners
4 cm
Face

Joiners connect the two faces of the non-load-bearing partition. The panel, supports and anchorage are coordinated with the building’s structural frame.

Dimension strips show the thickness allocation, not brace or joiner geometry. Central-zone widths are calculated from the overall thickness less the two 4 cm faces; braces, joiners and coordinated services occupy this space.

Thickness can be customized to the architectural requirements. Kitchen and bathroom panels are coordinated around the required plumbing thickness. Fine welded BRC mesh is used where specified; reinforcement and connections follow the approved engineering details.

Integration

Openings and services are designed in.

  • Doors and windowsCoordinate frames, openings, dimensions and interfaces before production.
  • Electrical and dataDefine conduits, outlet positions, distribution interfaces and access requirements.
  • Plumbing and sanitaryCoordinate pipe routes, fixture positions and site connection provisions.
  • Surface selectionRecord the approved finish family, colour, texture and physical sample reference.

Type 02 · The core interlocking product

Architecturally Finished
Interlocking Wall Block.

The supplied ARTSTONE datasheet shows the interlocking wall block through the front and rear faces, the engagement of two panels and the internal conduit channels.

Each interlocking wall block combines a finished architectural face with an interlocking rear geometry. Male projections engage with the matching female channels of the opposing element to form the dual-panel assembly shown in the sheet. Horizontal and vertical conduit channels are identified within the assembly for coordinated service provisions.

01 · Front isometric view: The finished architectural face (100) forms the exposed surface of the panel slab (101).
01 · Front isometric viewThe finished architectural face (100) forms the exposed surface of the panel slab (101).View in detail ↗
02 · Rear isometric view: The reverse shows male interlocking projections (102) and female interlocking channels (103).
02 · Rear isometric viewThe reverse shows male interlocking projections (102) and female interlocking channels (103).View in detail ↗
03 · Dual-panel assembly: Male and female features engage (104), with the horizontal conduit channel identified as 105.
03 · Dual-panel assemblyMale and female features engage (104), with the horizontal conduit channel identified as 105.View in detail ↗
04 · Isometric cutaway: The cutaway reveals the internal arrangement and the vertical conduit channel (106).
04 · Isometric cutawayThe cutaway reveals the internal arrangement and the vertical conduit channel (106).View in detail ↗

Component reference

The numbered product key.

ReferenceComponentWhat the drawing identifies
100Finished architectural faceThe exposed architectural surface.
101Panel slabThe base slab; the Foundation Series offering uses concrete.
102Male interlocking projectionsThe projecting features on the rear geometry.
103Female interlocking channelsThe receiving features for the matching projections.
104Male and female interlock engagementThe engagement shown in the dual-panel assembly.
105Horizontal conduit channelThe service channel identified in the assembly view.
106Vertical conduit channelThe service channel identified in the cutaway view.

Questions answered

Useful to know.

How do the wall classifications relate to the product formats?

The standard role classifications are the 25 cm structure wall and 15 cm partition wall, each with two 4 cm faces. Product format, module dimensions and assembly details are coordinated separately. The original interlocking-block datasheet illustrates geometry without stating dimensions; approved drawings establish the selected configuration.

Are fire, acoustic and thermal ratings guaranteed by this detail?

Performance must be established for the complete specified wall assembly, including joints, openings, penetrations and connections. Project engineering and relevant testing govern acceptance.

The next step

Let’s define your project.

Share your land details, intended use and priorities. We will discuss the appropriate package with you and your registered contractor.

Prepare your project brief ↗