Structure wall · 25 cm
Face17 cm central zone
Load-bearing concrete braces4 cm
Face
The concrete braces provide the central load-bearing arrangement. Brace geometry, reinforcement, foundations and connections follow the approved structural design.
Foundation Series
Choose a fully integrated customized wall made around your project, or an architecturally finished interlocking wall block. Each has a distinct product form and scope.

The Ready-to-Fix wall offering
A project-specific wall coordinated with its dimensions, architectural surfaces, doors, windows, fittings and specified building services.
Explore the customized wall ↓TYPE 02An architectural wall block with a finished face, male and female interlocking features, and channels shown in the product datasheet.
Explore the interlocking block ↓| Product | Defining form | Scope of integration |
|---|---|---|
| Fully Integrated Customized Wall | Wall produced to the approved project layout and dimensions. | Selected finishes, openings, fitted components and agreed building-service provisions. |
| Architecturally Finished Interlocking Wall Block | Interlocking block with an architectural face and matching rear geometry. | Male / female engagement and horizontal / vertical conduit channels as identified in the datasheet. |
Type 01
The customized wall is developed around the project’s layout, dimensions and architectural selections. Doors, windows, frames, fittings and specified electrical or plumbing provisions are coordinated before manufacture.
Its scope is defined as a wall package for the approved building, with the structural role, reinforcement, connections and site-completion interfaces established in the project design.
Customized-wall applications
Two structural classifications
Alongside the two product formats, Ready-to-Fix walls are classified by their role in the building. Both have a 4 cm concrete surface on each side. Their total thickness and central connections distinguish the structural and partition configurations.
| Classification | Total thickness | Two faces | Central arrangement | Building role |
|---|---|---|---|---|
| Structure wall | 25 cm | 4 cm on each side | Concrete braces within the central zone | Load-bearing, with braces and connections designed for the building loads. |
| Partition wall | 15 cm | 4 cm on each side | Joiners within the central zone | Non-load-bearing division of spaces within the structural system. |
Inside the wall
The concrete braces provide the central load-bearing arrangement. Brace geometry, reinforcement, foundations and connections follow the approved structural design.
Joiners connect the two faces of the non-load-bearing partition. The panel, supports and anchorage are coordinated with the building’s structural frame.
Dimension strips show the thickness allocation, not brace or joiner geometry. Central-zone widths are calculated from the overall thickness less the two 4 cm faces; braces, joiners and coordinated services occupy this space.
Thickness can be customized to the architectural requirements. Kitchen and bathroom panels are coordinated around the required plumbing thickness. Fine welded BRC mesh is used where specified; reinforcement and connections follow the approved engineering details.
Integration
Type 02 · The core interlocking product
The supplied ARTSTONE datasheet shows the interlocking wall block through the front and rear faces, the engagement of two panels and the internal conduit channels.
Each interlocking wall block combines a finished architectural face with an interlocking rear geometry. Male projections engage with the matching female channels of the opposing element to form the dual-panel assembly shown in the sheet. Horizontal and vertical conduit channels are identified within the assembly for coordinated service provisions.




Component reference
| Reference | Component | What the drawing identifies |
|---|---|---|
| 100 | Finished architectural face | The exposed architectural surface. |
| 101 | Panel slab | The base slab; the Foundation Series offering uses concrete. |
| 102 | Male interlocking projections | The projecting features on the rear geometry. |
| 103 | Female interlocking channels | The receiving features for the matching projections. |
| 104 | Male and female interlock engagement | The engagement shown in the dual-panel assembly. |
| 105 | Horizontal conduit channel | The service channel identified in the assembly view. |
| 106 | Vertical conduit channel | The service channel identified in the cutaway view. |
Questions answered
The standard role classifications are the 25 cm structure wall and 15 cm partition wall, each with two 4 cm faces. Product format, module dimensions and assembly details are coordinated separately. The original interlocking-block datasheet illustrates geometry without stating dimensions; approved drawings establish the selected configuration.
Performance must be established for the complete specified wall assembly, including joints, openings, penetrations and connections. Project engineering and relevant testing govern acceptance.
The next step
Share your land details, intended use and priorities. We will discuss the appropriate package with you and your registered contractor.